Autonics 2000 DPU Series Digital Thyristor Power Controllers

Original price was: $1,000.00.Current price is: $500.00.

Details:

  • Accurate feedback control (static current, static voltage, static power) by RMS measurement
  • Phase control and zero-crossing cycle control (fixed/variable cycle) methods for various load control
  • Remote monitoring and remote control
  • Supports Modbus RTU protocol by RS485 communication
  • Fast response speed by high-speed CPU
  • Built-in customizable 6 digital inputs (DI)
  • Basic variable alarm outputs; current error, heater disconnection (heater some disconnection-detection), etc.
  • Supports multi-input of a control input signal (current, voltage, potentiometer, etc)
  • Enables the install control part separately
  • Applicable load: all loads such as super kanthal, platinum, molybdenum, carbon, halogen lamp, chrome, nickel, etc.

Description

Brand Autonics
Model Number DPU Series Digital Thyristor
Control Phase Single Phase / 3-Phase
Rated frequency 50/60Hz (auto recognition), allowable frequency range: ± 2 Hz
Min. load Current 1 A
Output range Phase control: 0 to 98%, Z.C. control : 0 to 100%
Control Method
  • Phase control: normal/constant current feedback / constant voltage feedback / constant power feedback
  • Cycle control ( Z.C.): fixed cycle / variable cycle
  • ON/OFF Control (Z.C.)
digital input AUTO / MAN Selectable, RUN / STOP selectable, Reset, Output holding, SP set (SP 1 to 6)
Display Type Control Input, load voltage, load current, load power, load resistance, Power supply frequency
Min. display output Over 2.5% of rated voltage/current
RS485 comm. Modbus RTU method
Approval C ∈ EAC
Power supply 110 / 220 / 380 / 440 VAC ∼model ( fan and control power 220 VACs∼50/60Hz separately)
Allowable voltage range Single-Phase: 90 to 110% of power supply 3-phase: 85 to 115% of power supply
Power consumption Single-phase: ≤ 7 W ( except fan power ) 3-phase: ≤10 W ( except fan power )
Display method
  • Display value and setting value display: 7 segment 4-digit
  • State display: Single-phase LED × 4 , 3-phase LED × 6
  • Display value percentage display: 11 LED bar
Dielectric strength Between input terminal and power terminal:2000 VAC∼50/60Hz for 1 min
Vibration 0.75 mm double amplitude at a frequency of 5 to 55 Hz (for 1 min) in each X, Y, and Z direction for 2 hours
Insulation resistance ≥ 200 MΩ (500 VDC= megger)
Noise immunity ± 2 kV square waves noise (pulse width: 1μs) by the noise simulator
Ambient temp. -10 to 50°C, storage: -20 to 80°C (no freezing or condensation)
Ambient humidity 5 to 90%RH, storage: 5 to 90%RH (no freezing or condensation)